Residential Water Pump Installation: Pressure Tank or Tankless?
"Mahina ang tubig sa shower? Wala nang lumalabas sa taas?" The fix is the right water pump, installed the right way. This guide explains why you should never pump straight from the water meter, the three home setups (pressure tank, tankless booster and overhead tank), how to install a pump with a pressure tank step by step, how to set the pressure switch and tank, and the safety rules.
SHOP WATER PUMPS INSTALLATION STEPS ↓Watch: Bobby Explains Home Water Pump Installation
First Rule: Pump From a Tank, Not From the Meter
The 3 Home Setups
Fewer starts, steady water
The tank has a rubber bladder with air inside that stores water under pressure, so the pump doesn't start every time you open a faucet. Fewer on-off cycles, a longer pump life and steady pressure. Examples: Lotus LM100X jet pump with 24L tank · Shinsetsu SBJP-750 · Zekoki bladder pressure tank.
Compact and quiet
Starts only when a faucet opens. Inverter models keep the pressure constant even when several faucets run at once. But even a small leak makes it switch on and off again and again. Examples: Evergush auto booster · DAB Esybox Mini 3 (inverter).
Gravity does the work
The pump fills a roof tank and gravity brings the water down. You have water even during a brownout, but the pressure on the upper floor is weak.
Installing a Pump With a Pressure Tank
- Location: shaded, dry and ventilated, on a solid base, close to the water tank.
- Suction side: a short, airtight pipe the same size as the pump inlet or bigger. If the water is below the pump, add a foot valve and strainer.
- Discharge side, in order: check valve, union (for easy removal), gate valve, pressure gauge, then the pressure tank and pressure switch.
- Prime the jet pump before the first start: fill the pump casing with water.
- Electrical: its own breaker, the right wire size, and proper grounding.
Pressure Switch and Tank Settings
Pump starts at 20 psi
Example setting on a 20–40 psi pressure switch.
Pump stops at 40 psi
The pump fills the tank until it reaches this pressure.
2 psi below cut-in
Set it with the tank empty of water (about 18 psi for a 20 psi cut-in). Check it monthly.
Pro Tip: Add a Bypass Line
Safety Muna
- Never run the pump without water.
- Switch off the breaker before touching the pump.
Next Episode
Frequently Asked Questions
Pressure tank or tankless booster?
Can I connect the pump directly to the water meter?
What should the tank air pressure be?
Why do I need a check valve and a union?
Which pump size should I buy?
Pump, Pressure Tank, Pressure Switch and Check Valve
Lahat 'yan available sa KHM Megatools. May tanong ka pa? I-message mo lang kami, tutulungan ka naming pumili.
SHOP WATER PUMPS